Besoin d'un mode d’emploi pour votre REV LM-107B Détecteur de fumée ? Ci-dessous, vous pouvez consulter et télécharger gratuitement le mode d’emploi PDF en français. Ce produit a actuellement 3 questions fréquemment posées, 1 commentaire et 2 votes avec une note moyenne du produit de 0/100. Si ce n'est pas le mode d’emploi que vous souhaitez, veuillez nous contacter.

Votre produit est défectueux et le mode d’emploi n’offre aucune solution ? Rendez-vous à un Repair Café pour obtenir des services de réparation gratuits.

Mode d’emploi

Loading…

Smoke Detector Operating Manual
Type: LM-107B
This product has been tested according to EN 14604:2005 + AC: 2008
We recommend consulting a certified specialist for smoke detectors
for the planning and installation.
1. Technical Data
Smoke detector
Power supply 3V DC CR123A (Non-replaceable battery)
Cut-off voltage
for battery warning
2.2V
Current input Alarm Standby
≤ 120mA ≤ 2uA
Sound power level ≥ 85dB/3m
Temperature range -10°C~+40°C
Air humidity ≤ 95%RH
LED display Smoke detector functions
correctly.
LED (red) flashes every 344
seconds.
Alarm mode or test key
pressed.
The red LED flashes, the
warning sound is started.
Mute activation of the alarm
- mute operating mode).
The red LED flashes every
10 seconds,
this indicates mute
activation of the smoke
detector
Press the smoke detector
test key
to switch the alarm signal to
mute for some 9 minutes.
Alarm memory warning The green LED flashes every
43 seconds for 24 hours.
Battery (almost) discharged
Under normal conditions
the smoke detector has a
service life
of up to 10 years.
Exhaustion of the battery
capacity results in an audio
warning being sounded
every 43 seconds. This
audio warning sounds for
up to 30 days.
2. Technology / operation
General:
In areas where ventilation and/or air conditioning systems are used, is must
be ensured that air movement does not affect the function of the smoke
detector.
Smoke detectors must be permanently fixed on the ceiling. Mounting
instructions must be observed.
Choose a mounting method that ensures a holding force of at least 20N in
vertical direction.
The smoke detector is designed for monitoring residential buildings or
residential premises (not for industrial or commercial usage).
A function test must be performed on each smoke detector after installation.
The functionality of each installed smoke detector must be regularly checked
and maintenance measures must be ensured. Perform function test 1 x per
week, clean every 3 months.
3. Mounting locations
Mounting locations for smoke detectors:
Bedrooms, children’s rooms and corridors must be equipped (basic
requirement) with smoke detectors.
Always on the ceiling
50cm from the wall (or beam)
If the room is subdivided by ceiling-high furniture etc., a smoke detector must
be installed in each room partition
In rooms with a floor area of ≤ 60m², divided into ceiling boxes by beams or
joists, the following applies:
In ceiling boxes > 36m² a smoke detector must be installed per ceiling box
(see Figure 7a))
In rooms with a floor area of > 60m², an additional smoke detector must be
installed per 60m².
4. Planning examples
For apartments and single family homes
a) Example for use in an apartment
b) Example for use in a single-family home
Minimum requirements
Optimal installation
Restricted installation
5. Arrangement in special room geometries
Following distance ratios and arrangements are recommended for detector positioning:
a) Linear corridor
b) Rectangular corridor
c) Detector arrangement in large corridors
d) Detector arrangement in large corridors with corners
6. Constructional features
If a room is divided in height by a podium or a gallery, a smoke detector is required beneath
these installations if the area exceeds 16m² and the length and width exceed each 2m.
In rooms with ceiling slopes > 20° to the horizontal, a heat pocket can form at the top of the
ceiling which prevents smoke entry into the smoke detector.
Therefore, smoke detectors in these rooms must be mounted at least 0,5m but not more
than 1m from the ceiling top, see the following two illustrations.
Example of mounting with pedestal-shaped ceiling with a ceiling slope > 20°
Legend
1 = smoke detector
Remarks: Smoke detectors can be attached on the position left (1) or on the position right (2).
In rooms with a slope ≤ 20° smoke detectors must be mounted centrally on the ceiling.
In ceiling boxes ≤ 36m² and with ceiling slopes ≤ 20° as well as beams or joists with a
height ≤ 0.2m, the individual ceiling boxes are not taken into account (see Figure 7b)).
Install smoke detectors as centrally as possible in the room, in a ceiling box or on the joist.
In these rooms have beams or ceiling joists with a height > 0.2m, the smoke detector must
be installed on a beam or girder, as centrally as possible in the room (see section 7 Figure
c).
7. Notes for ceiling installation
For ceiling with joists – (height (h) of the joist ≤ 0.20m
and an area of the ceiling box >36m² or ≤36m²)
a) Example for ceiling
>36m²
Legend:
1 - Ceiling box
2 - Joist
b) Example of ceiling box ≤36m ²
Legend:
1 - Ceiling box
2 - Joist
c) Example of ceiling
with joist (height (h) of
the joist > 0,20m)
Legend:
1 - Ceiling box
2 - Joist
In corridors with a maximum width of 3m, the distance between two smoke detectors may not
exceed 15m. The detector distance to the front face of the corridor must not exceed 7.5m.
A detector must be arranged in crossings, junctions and corners (mitre line) of corridors. An
example of an arrangement is shown in section 5.
8. Mounting
Loosen the mounting plate on the rear side of the device by turning it clockwise.
Fix the mounting plate with the help of the enclosed mounting material to the ceiling or
wall. Check first whether the supplied mounting material is suitable for the structural
quality of the wall/ceiling.
Insert the smoke detector in the mounting bracket and rotate the smoke detector anti-
clockwise direction until it audibly engages.
Caution: Smoke detectors with replaceable battery can only be attached with inserted
battery because the latter have a locking mechanism.
On delivery of the smoke detector, the battery pin (red) is OFF (diagram below on l.).
To connect the smoke detector, move the battery pin (diagram below on r.).
Check functioning after the installation.
9. Operational test
Press the test/silent key. When the red lamp lights up rapidly in succession and the alarm
sounds at the same time, the smoke detector is working correctly.
The smoke detector then changes to the silent mode and the LED lights up every 10 seconds
After some 9 minutes, the smoke detector automatically changes to normal operations or
press the test key to end the silent mode.
Irregular or quieter sounds may point to a fault. Follow what is in the „Fault Finding“ chapter to
resolve the problem.
10. LED displays
Red LED lights up every 344 seconds: this indicates proper functioning of the smoke
detector.
Red LED flashes: when the test key is pressed or the smoke detector detects smoke
particles in the air (a constantly pulsating sound is also heard)
The flashing LED and alarm continue until there are no more smoke particles in the air or
the releasing key (test key) has been pressed.
Silent mode: when the smoke detector is in the silent mode (still), the LED lights up every
10 seconds.
Battery warning: A sporadic bleeping is heard and the LED lights up every 43 seconds. This
points to a low battery level.
You can switch off the alarm for 8 hours by keeping the test key pressed. The alarm
automatically switches itself on again after 8 hours.
Fault indication: the warning is given out every 43 seconds
Alarm memory: The smoke detector stores the alert once the alarm is given.
The green LED rapidly flashes 3 times in succession every 43 seconds.
As such, the user can later detect the alarm from some distance away without having to
touch the smoke detector.
The LED display is extinguished after 24 hours. A particular alarm signal is sounded when
you press the test key for the first time following an alarm. On
Actuating the test key the alarm memory is deleted. Now re-press the test key for the
renewed operational test.
11. Still alarm (silent mode)
Press the test key while the alarm sounds. As a result, the alarm is interrupted for 9 minutes.
The red LED flashes every 10 seconds thus indicating that the smoke detector is in the silent
mode (still) . The component has also been designed to minimize false alarms.
The alarm is brought into play after some 9 minutes should combustion particles continue to
be in the smoke detector. The silent mode can be repeatedly activated until those particles
which triggered the alarm are no longer in the air.
CAUTION: Before applying the silent mode, find out where the smoke is coming from
(source of the trouble) and ensure that no further danger proceeds from it.
DANGER: The fact of the alarm sounding without you carrying out any test means
that the smoke detector has detected smoke!
IMMEDIATELY FOCUS YOUR ATTENTION AND ACT ON ANY WARNING SIGNAL THAT
SOUNDS!
12. Cleaning /Maintenance
This includes at least a check of whether the smoke penetration openings are free (e.g.
covers, pollution caused by fluff and dust), whether there is function-related damage to the
smoke detector and whether the area of 0.5 m around the smoke detector is free of obstacles
(such as furniture) which inhibit the penetration of fire smoke into the smoke detector. If
contamination is detected in the smoke penetration openings, these should be cleaned
according to manufacturer instructions. If there is function-related damage to the smoke
detector, it must be replaced. If the installed smoke detector does not have the required
clearance around it, the mounting location must be inspected and a new location determined
if necessary.
13. False alarms
False alarms can be triggered by the following, for example:
welding and cutting work;
soldering and other hot work;
sawing and sanding work;
dust due to construction or cleaning;
water vapour, cooking vapours and odours;
extreme electromagnetic influences;
temperature fluctuations which lead to the condensation of the humidity in the smoke
detector.
In the event of works in the environment of the installed smoke detector which trigger false
alarms (e.g. renovation), the detector should be temporarily covered or removed. After
completion of the work, the original functionality of the installed smoke detector must be
restored as described in section 9.
Should the system report an alarm, please check whether the fire really exists. If so, call the
fire brigade.
If not, please check whether the mentioned reasons could have raised the alarm. We would
like to point out that we are not liable for the consequences of false alarms. We do not cover
any costs incurred by false alarms, such as from deployment of police, fire, or key services.
14. Troubleshooting
Problem Counter measures Solution
Smoke detector does not
sound when testing
Activate the smoke detector
before its installation
Position the battery pin
at ON
Clean the smoke detector Read the „Maintenance and
Cleaning „ section on this
Should, however, trouble
arise during the warranty
period
you can return the smoke
detector to your dealer‘s
The smoke detector bleeps
and the red LED flashes
every 43 seconds
The battery is down Replace the smoke detector
Irregular false alarms of
the smoke detector come
about or an alarm signal is
sounded when residents,
for instance, cook or take
a shower
Press the test key to stop
the alarm
Fit the smoke detector
somewhere else and press
the test key
The alarm sound is different
to what it usually is
Clean the smoke detector Read the „Maintenance and
Cleaning„ section on this
Should, however, trouble
arise during the warranty
period,
You can return the smoke
detector to your dealer‘s
15. WEEE-reference of disposal
In accordance with European defaults used electrical and electronics devices may
no more be given to the unsorted waste. The symbol of the waste bin on wheels
refers to the necessity of separate collection. Please help with environmental
protection and see to it that this device is given to the for this purpose designated
systems of waste sorting if you do not use it any longer.
GUIDELINE 2012/19/EU of the EUROPEAN PARLIAMENT AND the COUNCIL of July
04th 2012 about electrical and electronics old devices.
Batteries and accumulators are not to be disposed of in the normal house waste bin. Every
user is legally obliged, to hand over all batteries and accumulators, irrespective of
whether or not they contain harmful substances to a communal collection point in
the local town area or to a trade dealer so that they can be disposed of in an orderly
environmentally friendly manner.
Batteries and accumulators should only be handed over when they are completely
discharged!
REV Ritter GmbH
Frankenstr. 1-4
D-63776 Mömbris
Service-Phone: +49 900 117-1070
E-Mail: service@rev.biz
www.rev.biz
Declaration of performance “LE LM-107B” available at www.rev.biz.
GB
bedroom
kitchen
living room
children's roomchildren's room
bathroom
work room
kitchen
children's room
bedroom
living room
boiler room
>20°
0,5m
1
1
2
>20°
0,5m
2
ceiling
3
ceiling
4
ceiling
ceiling
1
5
ceiling
Red battery pin - OFF Battery pin after installation
OFF
ON OFF ON
TEST HUSH
T
W
I
S
T
T
O
R
E
M
O
V
E
T
W
I
S
T
T
O
T
I
G
H
T
E
N
D
O
N
O
T
P
A
I
N
T
Alarm display (red LED)
Test / Silence
Warning Alarm memory (green LED)
Loudspeaker
G216031
15
D.O.P.: 0832-CPR-F1314
EN 14604:2005/AC:2008
Leistungserklärung: LE LM-107B
ANL_LM-107B.indd 3 01.08.2017 09:52:08
Télécharger mode d’emploi en Français (PDF, 6.5 MB)
(Tenez compte de l’environnement et imprimez ce manuel uniquement si c’est vraiment nécessaire)

Loading…

Évaluation

Dites-nous ce que vous pensez du REV LM-107B Détecteur de fumée en laissant une note de produit. Vous voulez partager vos expériences avec ce produit ou poser une question ? Veuillez laisser un commentaire au bas de la page.
Etes-vous satisfait du REV LM-107B Détecteur de fumée ?
Oui Non
0%
100%
2 évaluations

Joignez-vous à la conversation sur ce produit

Ici, vous pouvez partager ce que vous pensez du REV LM-107B Détecteur de fumée. Si vous avez une question, lisez d’abord attentivement le mode d’emploi. La demande d’un mode d’emploi peut être effectuée en utilisant notre formulaire de contact.

Diogo 25-07-2020
Mon détecteur de fumée s'allume toujours tout seul même s'il n'y a pas de fumée

répondre | Cela a été utile (0) (Traduit par google)

En savoir plus sur ce mode d’emploi

Nous comprenons qu’il est agréable d’avoir un mode d’emploi papier pour vos REV LM-107B Détecteur de fumée. Vous pouvez toujours télécharger le mode d’emploi depuis notre site Web et l’imprimer vous-même. Si vous souhaitez disposer d’un mode d’emploi original, nous vous recommandons de contacter REV. Ils pourront peut-être fournir un mode d’emploi original. Recherchez-vous le mode d’emploi de votre REV LM-107B Détecteur de fumée dans une autre langue ? Choisissez votre langue préférée sur notre page d’accueil et recherchez le numéro de modèle pour voir si nous l’avons disponible.

Caractéristiques

Marque REV
Modèle LM-107B
Catégorie Détecteurs de fumée
Type de fichier PDF
Taille du fichier 6.5 MB

Tous les modes d’emploi pour REV Détecteurs de fumée
Plus de modes d’emploi de Détecteurs de fumée

Foire aux questions sur REV LM-107B Détecteur de fumée

Notre équipe d’assistance recherche des informations utiles sur les produits et des réponses aux questions fréquemment posées. Si vous trouvez une inexactitude dans notre foire aux questions, veuillez nous le faire savoir en utilisant notre formulaire de contact.

Où dois-je placer mon détecteur de fumée ? Vérifié

Cela dépend de la situation, mais dans une maison, il est préférable de placer au moins un détecteur de fumée à chaque étage. Essayez de les placer dans les corridors ou dans d'autres espaces qui relient les différentes pièces et ne placez jamais le détecteur de fumée directement à côté d'une cuisine ou d'une salle de bain. Gardez également un espace de 30 cm entre un détecteur de fumée et une lampe.

Cela a été utile (300) En savoir plus

Puis-je utiliser des bougies si je possède un détecteur de fumée ? Vérifié

Cela dépend en partie de la sensibilité du détecteur de fumée. Dans de nombreux cas, vous pouvez utiliser des bougies tant qu'elles ne sont pas placées à proximité directe du détecteur de fumée. L'extinction des bougies peut générer de la fumée et déclencher le détecteur de fumée.

Cela a été utile (59) En savoir plus

Un détecteur de fumée est-il pareil qu'un détecteur de monoxyde de carbone ? Vérifié

Non ! Un détecteur de fumée ne fonctionnera pas comme un détecteur de monoxyde de carbone et vice versa.

Cela a été utile (37) En savoir plus
Mode d’emploi REV LM-107B Détecteur de fumée

Produits connexes

Catégories associées